Ensure you have sufficient liquid when using auto-run modes!
Continuous mode - selects a duration for which the MicroFogger will stay activated
after the trigger is pressed. While running, continuous operation can be cancelled by
pressing SMOKE. Usually limited to 10s but with TIME LIMIT off, this is extended to 60s
Delay - Selects the duration for which the MicroFogger will wait until continuous mode is
activated. Requires continuous mode to be on in order to work. Limited to 15 minutes
Loop - Selects the number of operational loops that the MicroFogger will perform.
Requires continuous and delay mode to be turned on. Usually limited to 5 but with TIME
LIMIT off, this is extended to infinite loops (- - -)
RC channel - Allows adjustment of remote control channel. By default, all 4 channels
are in use for different power levels but once a specific letter is selected, the
MicroFogger will only respond to that button on the remote.
Accessory Menu - Press SELECT to enter this sub-menu. Press SMOKE to exit
Mode - Selects whether an accessory is always on (CONT) or only when
smoke is being generated (TRIG)
Diffuser power - Selects the power level for the diffuser accessory
Light mode - Selects the light accessory mode.
Color - Hold SELECT to cycle through 360 colors, white and RGB
Cycle speed - Selects how quickly a cycle of given light mode happens
RGB speed - How quickly the RGB spectrum cycles through colors
Advanced Menu - Press SELECT to enter this sub-menu. Press SMOKE to exit
These settings can be dangerous if adjusted improperly
RC program - Allows you to bind the MicroFogger to any 433mHz frequency
remote control. Simply press select and follow the on-screen instructions.
Remote ON/OFF/TRG - Lets you turn off the MicroFogger’s remote control
functionality to avoid unintentional activation during important performances.
When set to TRG, the RC will also activate auto-run modes
Time limit ON/OFF - Turns the time limit on or off. When off, the MicroFogger
will not stop after 10 seconds of continuous operation. It will also unlock
greater values in the continuous and loop mode menus. This is an advanced