If your phono section inverts phase, the hot color becomes the ground color.
Using tweezers or fine-tipped pliers, grip the center of the red wire’s connector not the wire
itself and push it onto the cartridge’s right hot terminal pin. Connect the remaining
connectors in the same way. To avoid damage to the cartridge, do not push the connectors all
the way on.
Place the Alignment Jig on the spindle with the V-groove against the base of the male bearing
shaft. Tighten the screws of the jig so it fits snugly against the male bearing shaft and over
the record spindle.
Place the arm tube assembly on the male pivot point, using caution with the 4-color wire and
Lemo connector. Set the arm in its rest. If the cartridge has a guard, remove it.
MAKE SURE THE MALE POINT IS IN THE CENTER OF THE FEMALE CUP, IT SHOULD FEEL SOLID
BUT YOU SHOULD BE ABLE TO SLIDE IT SIDEWAYS AND THE ARM RAISES AS YOU GO FROM
THE CENTER TO THE SIDES OF THE FEMALE BEARING. IT IS AN INVERTED CONE.
FEMALE BEARING
Use the arm rest all the time when not playing a record!!