EasyManua.ls Logo

W'eau WFI-028T - Drainage water in heat exchanger; To remove the compressor; Conduct regular maintenance

W'eau WFI-028T
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 19 -
such experiment.
8.4 Drainage water in heat exchanger
If the heat pump will be not used for a long time or in winter season, please do drain the water inside
heat exchanger to avoid broken when freezing.
8.5 To remove the compressor, please follow the following steps
Turn off the power supply
Exhaust the refrigerant from the low pressure end, attention to reduce the exhaust speed, and
avoid frozen oil leakage.
Remove the compressor air suction and exhausting pipe.
Remove the compressor power cables.
Remove the compressor fixing screws.
Remove the compressor.
8.6 Conduct regular maintenance according to the user manual instruction, to make sure
the unit running in good condition.
Fire prevention: if there is a fire, please turn off the power switch immediately, put the fire out with
fire extinguisher.
To prevent flammable gas: the unit working environment should stay away from gasoline, ethyl
alcohol and other flammable materials, to avoid explosion accident.