MICROFLUSH Toilet Manual 4 March 2005
DOUBLE CHECK
1.Air pressure at Microflush
toilet is at least 60-65 PSI.
2.Water Pressure at
Microflush toilet is between
20-50 PSI, 35 PSI optimal.
3.Water level in bowl should
be at top edge of flapper
opening.
4.If your Microflush does not operate correctly, refer to
troubleshooting sections.
FLUSH CYCLE ACTIVATORS
There are two types of Flush Activators:
Standard - hold handle or button down for 1 second.
Positive - barely push handle or button to activate.
CLEANING BLEED-OFF PLUG ASSEMBLY
Standard Flush:
Remove plug and clean with solvent; air blow dry.
Positive Flush:
Remove plug and clean with solvent; air blow dry;
remove and clean plug on Detent Valve.
Note: Use 5/32"or 4mm Allen wrench to remove plugs.
Note: Bleed-Off plugs on Air & Water Sequence Valves
and Detent Valves are different sizes that are not inter-
changeable.
MAINTENANCE/CLEANING/CLEARING/
WINTERIZING
ROUTINE MAINTENANCE
Your Microflush toilet has an
air-operated Air/Water Se-
quence Valve which requires
periodic lubrication with a
silicone based lubricant.
Check your application at right to determine how often to
lubricate your Air/Water Sequence Valve. The Air
Cylinder should be serviced if you have to take up your
Microflush toilet for any reason. The air system must be
free of moisture. Drain air receiver regularly to
remove moisture.
CLEANING
Use Micro-Clean Organic Spray Cleaner, P/N 24542.
Sanitizers like Lysol, Pine-Sol, Hexol, ammonia base
products, caustic drain openers or non-biodegradable
cleaners should never be used if the plumbing system
is connected to a Microphor Marine Sanitation
Device.
1.While depressing the Flush Activator, turn OFF the
water. Allow the bowl cleaner to flow into the lower
chamber.
Keep the Flushing Activator depressed.
2.Insert bowl brush into lower chamber and agitate
mixture carefully. Remove the bowl brush and
release the flush activator.
3.Turn the water ON and flush twice to rinse thor-
oughly.
Use MicroScrub, P/N 24827, to clean the hopper.
1.Turn off water and depress flush activator.
2.Dispense 1/2 bottle of MicroScrub into the hopper.
3.Turn on water and allow MicroScrub to stay in the
hopper as long as possible before flushing.
CLEARING YOUR MICROFLUSH TOILET
If your Microflush toilet becomes plugged, shut off the
water supply, press the flush handle and hold. The
flapper will remain open until flush handle is released.
Check to see if the restriction can be removed from lower
portion of Microflush toilet with a hooked wire, being
careful not to damage the rubber seal on the flapper or
the mating surface on the hopper. If obstruction cannot
be picked out with a hook or tongs, use plunger by
pushing in slowly and pulling out quickly to pull object
back into the hopper. If necessary, turn air off and use a
snake inserted through a short plastic pipe placed in
hopper. Pipe will protect flapper seal. If valve will not
operate with water off, hold flush lever down and turn
water on and off quickly to free valve action. When the
Recommended
Water Level
Bleed-Off Plug Assembly
Bleed-Off Plug
Detent Valve
Positive Flush
File: Timing
USAGE LUBRICATE
Light Every 5 years
Medium Every 2-3 years
Heavy Every year