EasyManuals Logo

Wacker Neuson BH 22 User Manual

Wacker Neuson BH 22
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Maintenance
T00932GB.fm 24
7.2.3 Spark plug: Clean dirty or wet spark plugs. Check spark plug gap (0,5
mm).
7.2.4 Ignition: Gap between fan 0,3 - 0,4 mm.
7.2.5 Cylinder: Keep cooling fins clean.
7.2.6 Rewind starter: Oil bearing bolt lightly after approx. 200 hours of
operation.
7.3 Percussion system, crankcase
Special Lubricating Grase (see technicla data)
Grease check
7.3.1 Grease breaker once a month by way of the red grease fitting of the
crankcase.
7.3.2 Renew grease in bearings of crank mechanism every 600 hours of
operation. Wash bearings thoroughly in appropiate cleaning fluid and
fill approx. 2/3 full with grease. Make sure not to fill in a greater or
lesser amount than that specified.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson BH 22 and is the answer not in the manual?

Wacker Neuson BH 22 Specifications

General IconGeneral
BrandWacker Neuson
ModelBH 22
CategoryPower Tool
LanguageEnglish

Related product manuals