EasyManua.ls Logo

Wacker Neuson DPU 6555He

Wacker Neuson DPU 6555He
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
T01006GB.fm 28
4.2 Mechanical oil pressure control
It is necessary to reactivate the mechanical oil pressure control in the following
cases:
after the initial filling - first filling - of the fuel tank or if the tank has run
dry.
in the case of an automatic engine stop due to an inefficient engine oil
supply.
after freeing the engine when in presence of extremely low
temperatures.
1. Fill up fuel tank.
2. Check engine oil level.
3. To activate depress hand lever „d“ for approx. 5 seconds.
4. Check to see that the engine does not leak.
5. Start engine.
d

Related product manuals