Maintenance
T01007GB.fm 49
5.7 Exciter
5.7.1 Check oil level:
1. Position vibration plate horizontally.
2. Open filler bore (40).
3. The oil level must reach the start of the thread of the filler bore (40).
4. If necessary, pour in oil (see Technical Data) through filler bore (40)
(use funnel 0,75 l).
5. Close filler bore (40). (torque setting = 100 Nm)