10 Troubleshooting
56 100_0202_ts_0010.fm
Error code Display Possible causes Remedial measure
1 Oil pressure
shutdown
Engine oil level is too low. 1. Deactivate machine.
2. Top up motor oil.
Oil pressure switch or electrical
connection is defective.
Have the machine repaired.*
2 Excess temperature
shutdown
Coolant level is too low. Top up coolant.
Cooling system is leaking. Have the machine repaired.*
Engine is overheated. Allow engine to cool down.
Cooling fins of the cooler are dirty. Blow cooling fins with
compressed air from the
inside to the outside from a
safe distance.
Temperature sensor or electrical
connection is defective.
Have the machine repaired.*
Electric fan is defective.
3 Peak in the mains
supply shutdown
Charge controller or electrical
connection is defective.
4 Battery error Alternator, charge controller, battery, or
electrical connection is defective.
5 Charge controller/
generator shutdown.
Alternator, charge controller, or electrical
connection is defective.
6 Battery error Alternator, charge controller, battery, or
electrical connection is defective.
7 Check air cleaner Air cleaner cartridge is dirty. Replace air cleaner
cartridge.
Electrical connection of the air cleaner
sensor is defective.
Have the electrical
connection of the air cleaner
sensor checked.*
8 Air cleaner error Air cleaner sensor is defective. Have the machine repaired.*
Electrical connection of the air cleaner
sensor is defective.
Have the electrical
connection of the air cleaner
sensor checked.*
9 Oil pressure switch
shutdown
Oil pressure switch or electrical
connection is defective.
Have the machine repaired.*
10 Charge controller
error
Charge controller or electrical
connection link to the generator is
defective.
11 Charge controller/
generator error.
Alternator, charge controller, or electrical
connection is defective.
12 Overload shutdown Machine is overloaded, because the soil
density is too high.
Deactivate the machine and
then re-activate it.
To prevent overload, observe the following rules:
Avoid operation on soils that are too hard to compact.
Reduce the compaction performance by actuating the slow / fast
rocker switch.
Switch-over from fast to slow operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU80 Series and is the answer not in the manual?

Wacker Neuson DPU80 Series Specifications

General IconGeneral
BrandWacker Neuson
ModelDPU80 Series
CategoryPower Tool
LanguageEnglish

Related product manuals