Operator's manual
Vibratory plate
DPU
80, 90, 110
Model DPU
Document 5100008833
Issue 06.2016
Version 06
Language en

Table of Contents

Questions and Answers

  • Z
    zsheppardSep 3, 2025
    What does it mean if Wacker Neuson Power Tool control lamp illuminates red?
    • S
      Stephanie HoodSep 4, 2025
      If the control lamp illuminates red on the Wacker Neuson Power Tool, it could indicate that the machine is in the warm-up phase. Wait until the warm-up phase has completed. It may also indicate that the diagnostic system has detected an error. Check control lamps and fault indications on the display.
  • D
    Daniel MckenzieSep 18, 2025
    What to do if Wacker Neuson Power Tool experiences overload shutdown?
    • R
      Richard HendersonSep 18, 2025
      If the Wacker Neuson Power Tool experiences an overload shutdown, it is because the machine is overloaded due to high soil density. Deactivate the machine and then re-activate it. To prevent future overloads: * Avoid operation on soils that are too hard to compact. * Reduce the compaction performance by actuating the slow / fast rocker switch. * Switch over from fast to slow operation.
  • K
    Karl HayesSep 16, 2025
    What to do if Wacker Neuson Power Tool experiences automatic start error?
    • C
      cruzrachelSep 16, 2025
      If the Wacker Neuson Power Tool experiences an automatic start error, it could be due to: * An empty fuel tank. Top up the fuel. * A defect in the fuel system. * Engine, diesel valve, or electrical connection of the diesel valve is defective.
  • P
    Patricia PollardSep 14, 2025
    What to do if Wacker Neuson Power Tool shows check air cleaner?
    • J
      Jessica SilvaSep 14, 2025
      If the Wacker Neuson Power Tool indicates 'check air cleaner', it could be due to: * A dirty air cleaner cartridge. Replace the air cleaner cartridge. * A defective electrical connection of the air cleaner sensor.
  • R
    Rebekah HarrisSep 13, 2025
    How to call up diagnostics menu on Wacker Neuson Power Tool?
    • C
      carlagarzaSep 13, 2025
      To call up the diagnostics menu on the Wacker Neuson Power Tool, continuously press the ON/OFF switch of the machine for at least three seconds.
  • J
    Janice GarciaSep 12, 2025
    What does it mean if Wacker Neuson Power Tool charging control lamp lights up red when the engine is running?
    • A
      apetersonSep 12, 2025
      If the charging control lamp lights up red when the engine is running on your Wacker Neuson Power Tool, it indicates an error in the electric system.
  • C
    carterannaSep 9, 2025
    What to do if Wacker Neuson Power Tool experiences excess temperature shutdown?
    • A
      Aaron AndersonSep 9, 2025
      If the Wacker Neuson Power Tool experiences an excess temperature shutdown, possible causes include: * Coolant level is too low. Top up the coolant. * The cooling system is leaking. * The engine is overheated. Allow the engine to cool down. * The cooling fins of the cooler are dirty. Blow cooling fins with compressed air from the inside to the outside from a safe distance. * The temperature sensor or electrical connection is defective.
  • T
    Timothy KellerSep 7, 2025
    What to do if Wacker Neuson Power Tool experiences oil pressure shutdown?
    • P
      Patrick JimenezSep 7, 2025
      If the Wacker Neuson Power Tool experiences an oil pressure shutdown: * It may be because the engine oil level is too low. Deactivate the machine and top up the motor oil. * The oil pressure switch or electrical connection is defective.
  • L
    Laura AlvaradoSep 5, 2025
    What does it mean if Wacker Neuson Power Tool control lamp flashes red?
    • X
      Xavier DavisSep 5, 2025
      If the control lamp flashes red on the Wacker Neuson Power Tool, it means the machine is overloaded because the soil cannot be compacted any further. To resolve this: * Avoid operation on non-compactable soil. * Reduce the compaction performance by actuating the slow / fast rocker switch. * Switch over from fast to slow operation.
  • N
    Nicholas WelchAug 21, 2025
    Why Wacker Neuson Power Tool motor will not start?
    • D
      David LevineAug 21, 2025
      The Wacker Neuson Power Tool motor might fail to start due to several reasons: * The emergency stop switch may be pressed. If so, unlock it. * The machine might not be activated; in that case, activate it. * The starter battery could be discharged. Try loading the starter battery or performing a jump-start. * The oil level might be low. Top up the oil and actuate the valve hood on the oil filter housing. * The fuel level could be low, so top up the fuel. * A defective starter motor, remote control, decoder, or wiring harness.

Summary

Security and Operator Responsibilities

Safety Policy, Proper Use, and Operator Responsibilities

Covers safety policy, correct usage, and the operator's defined responsibilities.

General Security Instructions

Personnel Qualification and General Safety Instructions

Details personnel qualification requirements and general safety guidelines.

Specific Security for Vibratory Plates

Specific Safety for Vibratory Plates and Handling

Safety instructions specific to vibratory plates, including operational safety and handling.

Personal Protective Equipment and Safety Devices

Personal Protective Equipment and Safety Devices

Lists required PPE and explains the function of safety devices on the machine.

Safety Shutdowns and Emergency Procedures

Safety Shutdowns and Emergency Procedures

Covers safety shutdowns for remote operation and behavior in dangerous situations.

Setup and Function Overview

Remote Control Operation Principles

Explains the principles of remote control operation and infrared transmission.

Components and Operators Controls

Machine Component Identification

Identifies and describes the main physical components of the vibratory plate.

Operator Controls and Panel Indicators

Operator Controls and Their Functions

Details the various controls on the machine and their specific functions.

Control Panel and Display Information

Diagnostic and Configuration Menu Operations

Remote Control Unit Details

Transport Procedures

Machine Lifting and Securing

Operation and Use: Pre-Operation

Operation and Use: Notes and Slopes

Operation and Use: Commissioning

Operation and Use: Activation

Operation and Use: Commissioning Methods

Operation and Use: Start and Compatec

Operation and Use: Center Pole Control

Operation and Use: Remote Control

Operation and Use: Shutdown Procedures

Emergency Stop and Machine Deactivation

Remote Control Battery Charging

Transmission Channel and Diagnostics

Error Memory and Configuration Menu

Maintenance Schedule

Periodic Maintenance Tasks

Long-Interval Maintenance and Fuel

Machine Cleaning and Engine Oil

Motor Oil and Filter Replacement

Air Cleaner Maintenance

Coolant Level Management

Exciter Oil Level Management

Hydraulic Oil and Connections Maintenance

Troubleshooting Machine Issues

Machine Troubleshooting: Faults, Causes, and Remedies

A table listing common machine faults, their possible causes, and remedial measures.

Troubleshooting: Units and Lamps

Receiving Unit and Control Lamp Fault Diagnosis

Tables for troubleshooting issues with receiving units and center pole control lamps.

Remote Control Troubleshooting

Remote Control Troubleshooting Guide

A chart to diagnose and resolve problems related to the remote control unit.

Display Faults and Error Handling

Display Fault Indications and Error Message Handling

Lists fault indications on the display and procedures for handling error messages.

Troubleshooting Error Codes Part 1

Troubleshooting Error Codes (1-12)

Lists error codes, their display messages, causes, and remedies.

Troubleshooting Error Codes Part 2

Troubleshooting Error Codes (13-21)

Continues listing error codes, their display messages, causes, and remedies.

Troubleshooting Error Codes Part 3

Troubleshooting Error Codes (22-35)

Continues listing error codes, their display messages, causes, and remedies.

Jump Starting Procedure

Technical Data: DPU80

DPU80 Model Specifications

Detailed technical specifications for the DPU80 vibratory plate.

Technical Data: DPU80 r

DPU80 r Model Specifications

Detailed technical specifications for the DPU80r vibratory plate.

Technical Data: DPU90

DPU90 Model Specifications

Detailed technical specifications for the DPU90 vibratory plate.

Technical Data: DPU90 r

DPU90 r Model Specifications

Detailed technical specifications for the DPU90r vibratory plate.

Technical Data: DPU110

DPU110 Model Specifications

Detailed technical specifications for the DPU110 vibratory plate.

Technical Data: DPU110 r

DPU110 r Model Specifications

Detailed technical specifications for the DPU110r vibratory plate.

Technical Data: Combustion Engines

Technical Data: US Combustion Engines

Wacker Neuson DPU80 Series Specifications

General IconGeneral
BrandWacker Neuson
ModelDPU80 Series
CategoryPower Tool
LanguageEnglish