EasyManuals Logo

Wacker Neuson G 14 User Manual

Wacker Neuson G 14
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Maintenance G 14
50 wc_tx001169gb.fm
6.4 Checking the Engine Oil
Prerequisites
Engine is stopped
Machine is on a level surface
Fresh oil is available (see Technical Data for type and quantity)
When
Check engine oil daily before starting the engine, or more than 5 minutes after
stopping the engine.
Procedure
Follow the procedure below to check the engine oil level.
1. Remove the oil level gauge (b).
2. Wipe the oil level gauge clean and re-install it.
3. Remove the oil level gauge again and check the oil level. The oil level should fall
between the upper and lower mark (A).
4. If the oil level is too low, remove the filler cap (c) and add oil to the prescribed
level.
5. Wait at least five minutes for the oil to drain into the oil pan, and check the oil
level again.
6. Re-install the filler cap when the oil is at the prescribed level.
WARNING
Burn hazard. Engine, muffler, and exhaust pipes become extremely hot during
operation.
f Stop the engine and allow the machine to cool before checking the engine oil.
b