1A-11
G2.5A OPERATION 1A
f
c
2
c
1
1015SD03 1015SD04
1005SD47
1005SD49
e
1
e
2
CHOKE
d
1
d
2
1.16 To Start
Before starting, be sure you read and understand all the
safety and operating instructions in this manual.
1. Disconnect all loads from the generator.
2. Open fuel valve by moving lever to the right (c
1
).
Note:
If engine is cold, move choke lever to closed
position
(d
1
).
If engine is hot, set choke to open
position
(d
2
).
3. Turn engine switch to “ON” (e
1
).
4. Pull starter rope (f).
Note:
If the oil level in the engine is low, the engine
will not start. If this happens, check oil level and add
oil as needed.
5. As engine warms up move choke lever to OPEN
position (d
2
).
6. Allow engine to warm up a few minutes before attach-
ing loads.
1.17 To Stop
1. Turn off and disconnect all tools and appliances
attached to the generator.
2. Turn engine switch to “OFF” (e
2
).
3. Close fuel valve by moving lever to the left (c
2
).
Note:
To stop engine quickly in an emergency, turn
engine switch to "OFF"
(e
2
).
1.18 Operating Heavy Loads
Limit operations requiring the maximum rated output
of 2500 W to 20 – 30 minutes. For continuous operation
do not exceed the continuous rated output of 2250 W.
CAUTION: DO NOT exceed the current limit specified
on the control panel for any one receptacle.