1.28 Storage
Before storing generator for a long period of time:
1. Close the fuel valve and remove and empty sediment
cup under carburetor.
2. Disconnect the fuel line from the carburetor. Place
open end of fuel line into a suitable container and open
fuel valve to drain fuel from tank.
3. Loosen the drain screw on the carburetor and drain
any remaining fuel from carburetor.
4. Change the engine oil.
5. Remove the spark plug and pour approximately one
tablespoon (1 ounce) of clean engine oil into the
cylinder. Crank the engine a few turns to distribute the
oil to the inside of the cylinder walls.
6. Pull the starter rope slowly until resistance is felt and
leave handle in this position. This ensures that the
intake and exhaust valves are closed.
7. Store generator in a clean, dry area.
Gasoline is extremely flammable. Drain fuel tank in
a well-ventilated area. DO NOT drain tank in an area
with flames or sparks.
1.29 Troubleshooting
If engine doesn't start, check that:
1. Engine switch is on "Start".
2. Fuel valves under fuel tank and on engine are open.
3. Fuel tank has fuel.
4. Choke lever is in correct position. Choke should be
closed when starting a cold engine.
5. All loads are disconnected from generator.
6. Spark plug is in good condition.
7. Spark plug cap is tight.
8. Engine oil level is adequate.
If engine starts but there is no power at receptacles,
check that:
1. Circuit breaker is closed.
2. Connector from generator to control panel is tight.
WARNING
!