GP Repair Technical Data
wc_td000169gb.fm 23
Item No. GP 6600A CAN
0620045
GP 6600A CAN
0620046
GPS 6600A CAN
0620047
Generator
Maximum Output
W
6600
Continuous Output
W
5500
Type Dual voltage, single phase,
Auto voltage regulator system
AC Voltages
available
volts
phase
120 / 240
Frequency
Hz
60
Power Factor 1.0
AC receptacles:
125V GFI duplex
125V GFI duplex
125V twist-lock
125V/250V twist-lock
amp
amp
amp
amp
20
20
30
30
Main Circuit Breaker
amp
2-pole, 27 amp each pole
L x W x H
mm
(in.)
685 x 530 x 520
(27 x 21 x 20.5)
1005 x 685 x 660
(39.5 x 27 x 26)
870 x 530 x 520
(34.3 x 21 x 20.5)
Weight (dry)
Kg (lbs.)
87 (192)
96.6 (213)
94 (207.5)