3. Re-install the fuel tank cap, and close the fuel tank cap cover.
Draining the
carburetor
4. Place a plastic cloth and a collection container beneath the machine.
5. Using a flat screwdriver or a coin, unscrew and remove the left side cover (c)
from the generator enclosure.
6. Locate and remove the fuel drain screw (e). Fuel will drain from the attached
plastic tube.
7. Collect and dispose of drained fuel.
8. Re-install the fuel drain screw.
9. Re-install the left side cover.
Change the
engine oil
See Changing the Engine Oil.
Check
fasteners
Check the machine for loose or missing fasteners. Tighten or replace as needed.
Clean
generator
body
10.Using a clean, dry shop cloth, wipe the outside of the machine thoroughly to
remove dust and contaminants.
11.Spray the machine with a protectant such as Armor-AllĀ®.
NOTICE: Do not use water to clean the machine! Water is corrosive and can
permanently damage the machine and operating electronics.
Store the
generator
12.Pull the starter handle until resistance is felt. Leave the handle in this position.
13.Store the generator in a well-ventilated, low humidity area.
wc_gr006661
c
e
e