25
AG 19
GB
Adjusting the Packing Seal Assembly
i
There is a hole in the cap (1). If coating medium is discharged
from this hole, the packing requires adjustment
1. Unscrew the cap (1) with a screwdriver, then remove the spring (2).
2. Use box spanner 10 mm (4) to turn the pressure plate a quarter turn to
the right.
3. Replace the spring (2) and tighten the cap (1) as far as the stop.
If the problem persists, please consult your WAGNER service center.
1
2
3

Related product manuals