5
6
7
8
9
P. 11
10 11 12
18
EN
CLEANUP CONTINUED
5. Point the spray gun at the side of a waste container.
Ground the gun against the side of a metal waste
container if ushing with mineral spirits.
While squeezing the trigger, turn the pressure control knob to
‘2’, and turn the PRIME/SPRAY knob to SPRAY.
6. Continue squeezing the trigger until uid is coming out clear.
You may need to get new cleaning solution.
7. Perform Pressure Relief Procedure, page 9.
8. Remove the inlet lter by pulling if o the suction tube. Clean
by hand using a soft-bristled brush.
Remove the tip guard and spray tip from the cleaning solution.
Clean by hand using a soft bristled brush.
Make sure the opening in the black housing on
the suction tube that the inlet lter attaches to is
completely clean and free from spray material.
9. IMPORTANT STEP: Fill a bucket with warm, soapy water.
Following steps 5-7 in the “Spraying” section, spray at least one
gallon of warm, soapy water. This will ensure that the spray tip
will be completely clean for the next use.
10. Perform Pressure Relief Procedure, page 9. Remove the suction
tube. Run water from a faucet through the tube to ush out any
remaining material. Do not reinstall the suction tube.
11. Remove the spray tip assembly.
Repeat step 5 from above, continuing to squeeze the trigger
until no uid comes from the gun (this will purge any remaining
water in the spray hose).
Turn PRIME/SPRAY knob to PRIME. Turn power OFF.
tention
Do not allow the pump to run for more than one
minute without uid.
12. Reattach both the inlet lter and spray tip/tip guard assembly.