Operating manual Manual Powder System SPRINT XE
3 Identification
Order number 2354920 | Edition 01/2023 9
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
3.1.1 Trolley identification
Device type Airfluid XE trolley/60L XE trolley
manufacturer Wagner International AG
9450 Altstätten
Switzerland
II3DExhIIIBT100°CDc
CE European Communities
Ex Symbol for explosion protection
II Device class II
3 Category 3
D Ex-atmosphere dust
Ex Ignition protection class
h Ignition protection class for non-electrical devices
IIIB Explosion group (dust group)
T100°C
Temperature class, maximum surface temperature < 100 °C; 212 °F
Dc Device protection level, suitable for use in Zone 22
3.1.2 Control unit identification
The device is suited for use in potentially explosive areas, in accordance with Test Certificate
PTB12ATEX5001.
Device type EPG-Sprint XE control unit
manufacturer Wagner International AG
9450 Altstätten
Switzerland
0102
II3(2)DIP6480°C
CE European Communities
0102 Number of notified body which issues the recognition of quality
assurance in production.
Ex Symbol for explosion protection
II Device class II
3 Category 3 (zone 22)
(2) Impact on equipment of category 2
D Ex-atmosphere dust
IP 64 Protection class IP64
80°C
Temperature class, maximum surface temperature < 80°C;
176 °F