11
VM 2000



"?
OPERATING MANUAL
EDITION 03 /2007
PART NO. DOC0388871
4.3 TECHNICAL DATA
Input voltage: 115VAC 50/60Hz
230VAC 50/60 Hz k
Input power: max. 30 W
Output voltage: max. 17 Vpp
Output current: max. 0.9 A
High voltage limit 80 kV DC
Corona current limiting: 100 µA DC
Polarity: for positive and negative HV generators
Enclosure class: IP 54 *
Weight (without cable) 3.2 kg; 7.1 lb
Working temperature range 5-40°C; 41-104°F
Dimension width (B) 180 mm; 7.09 in
Dimension height (H) 145 mm; 5.71 in
Dimension depth (T) 265 mm; 10.43 in
* unit is only splash-proof if retaining straps interlock the spray gun cable box with the
mains connector and the power cable box with the control unit connector.