EasyManua.ls Logo

WAGNER VM 2000 - Troubleshooting and Maintenance

WAGNER VM 2000
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
VM 2000
(6-
/&&
+6
M
/.




















6-
"?
OPERATING MANUAL
EDITION 03 /2007
PART NO. DOC0388871
6 TROUBLESHOOTING AND MAINTENANCE
Problem Cause Solution
Green LEDs (3) (4) do not
light up
• Mains power not switched on
• 0.5 / 1.6 A slow-blow fuses
defective
• Switch on mains power supply
• Replace fuses
Red LED (5) lights up (no
high-voltage supply)
• HVM-mdule defective • Inform your local WAGNER Service
Center
Red LED (6) lights up (no
high-voltage supply)
• Open circuit in the connecting
lead to the spray gun
• Earth connection between control
unit and spray gun interrupted
• Connecting lead can be replaced by
WAGNER Service
• Inform your local WAGNER Service
Center