Revision 15
21
A few important settings and their default states are given in Table 4.
Setting Name
Default State
Description
Exclusivity
Disabled
This prevents more than one outlet
being operated at a time.
Water Lockouts
Disabled
See Table 5 on page 23 for more
information on this setting.
IR sensor Inputs
Disabled, unless
factory set to Enabled
See Table 5 on page 23 for more
information on this setting.
Dual Flush
(Double Press)
Disabled
See Table 5 on page 23 for more
information on this setting.
Date & Time (RTC)
The current date and time must be
set for some unit functions to
operate correctly. The unit will
default on power up to a specific
date and time, however, this date
must be modified. The blinking
message Set Date & Time appears
on a new unit during first power up
or whenever the correct date and
time is lost because of a power
failure. The default date and time is
then applied. The unit has a
minimum backup supply of 48 hours
to avoid immediate loss of the date
and time settings. See Table 5 on
page 23 for instructions on setting
the date and time.
Time Slots
All
Default setting is All, which does not
restrict product usage.
Refer to Table on page 23.
Hygiene Purge
Off
Refer to Table on page 23.
Remote (AUX) Input
set up
E - Remote Lockout
F - Remote Flush
G - Half flush
The three Remote inputs can be
assigned to operate any of the
remote functions.
Table 4. Important settings
The Lockout function is used to prevent misuse of the sanitary facilities. The
function is used to limit the number of operations of any valve within a specified
time period.
When the Lockout function is enabled, the hot and cold basin/bath outlet can be
operated for a maximum of 10 times over a 1-hour period, the shower 4 times
over a 1-hour period and the WC 4 times over a 15-minute period.
When the maximum permitted number of operations for any valve is exceeded the
valve is locked out (inoperable) for one hour in case of the basin and showers and
15 minutes for the WC flush valve. The settings for the Lockout feature can be
adjusted. The Lockout feature can also be enabled or disabled. The Lockout