93.8
7 Nm
5.2 lbft
3.69
Emergency
manual override
Coil operating features
Nominal voltage tolerance : ±10%. . . . . . . . .
Power rating : 36 W. . . . . . . . . . . . . . . . . . . .
Coil insulance : class H. . . . . . . . . . . . . . . . . . .
Duty cycle : 100%. . . . . . . . . . . . . . . . . . . . . .
0
100
200
300
400
0 15 30 45
Operating condition diagram
Flow
Pressure
(l/min)
(bar)
Operation area
(psi)
4500
3000
1500
P Þ B
A Þ T
P Þ A
B Þ T
8ES solenoid control
Complete control
201
8ES1 kit
single acting on A
8ES3 kit
double acting
8ES2 kit
single acting on B
23.5
Allen wrench 4
6.6 Nm / 4.9 lbft
Wrench 13
24 Nm / 17.7 lbft
Wrench 22
24 Nm / 17.7 lbft
Spool
Connection ISO4400
(needs C02 connector,
see page. 62)
Conn. 1 Conn. 2
+--
Electric wiring example
To battery
Connector 1 Connector 2
0.93
Operating features
Internal leakage A(B)®T
(Dp = 100 bar -- 1450 psi
T = 40°C -- 104°F) : 10 cm
3
/min -- 0.61 in
3
/min. . . . . . . . . . . . . . . .
4 8
(US gpm)
12
01
20
2
1
2
1
SD5
39DAT003A