Page 15 of 34
6.7 Pipework Configurations Heat Pump models
Figure 5b: Typical pipework configuration, Heat Pump models
Pipe work accessory kits can be used to complete the installation comprising of flanged
connections, sealing washers and other fittings. Ensure the connections are clean and tight.
Additional details are included with the accessory kit, see document Q12-084.
HOT OUTLET
COLD INLET
Balanced Supply
to cold taps
Discharge
1
2
3
4
Plate Heat
Exchanger,
see Figure 5c
6
7
Mains stopcock (not supplied)
Inlet group
Temperature & pressure relief valve
Tundish
Plate Heat Exchanger
Expansion vessel
Drain cock (not supplied)
Potable water circulating pump
1
2
3
4
5
6
7
8
5
8