s1fmdl1sm-REV1207 Model S1F Metallic Page 28
This 8 foot long (244 centimeters) Ground
Strap part number 920-025-000, can be
ordered as a service item.
To reduce the risk of static electrical sparking,
this pump must be grounded. Check the
local electrical code for detailed grounding
instruction and the type of equipment required.
Grounding The Pump
Take action to prevent static
sparking. Fire or explosion can
result, especially when handling
flammable liquids. The pump,
piping, valves, containers or other
miscellaneous equipment must
be grounded.
WARNING
One eyelet is installed to a true earth ground.
(Requires a 5/16 or 8mm maximum diameter bolt)
One eyelet is fastened to the pump hardware.
To be fully groundable, the pumps must be ATEX
Compliant. Refer to pump data sheet for ordering.