EasyManua.ls Logo

Wascomat SU620 - Preventive Maintenance; Daily; Every Third Month

Wascomat SU620
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
107
Preventive maintenance
To maintain correct and proper functioning and to prevent interruption of
service, the following maintenance scheme should be adhered to.
The maintenance interval should be adapted to how frequently the machi-
ne is used.
Daily
• Checkthedooranddoorlock:
- Let the door remain open and try starting the machine. The machine
should not start.
- Close the door, start the machine and try opening the door. It should
not be possible to open the door until the drum has stopped turning.
- Check that the door does not leak.
- Clean the door seal, removing any detergent and fluff.
• Checkthatthedrainvalvedoesnotleakduringthewashcycle.
• Cleanoutanydetergentremaininginthedetergentcompartment.Rapid
advance through a program and let the water rinse the compartment:
Every third month
May only be carried out by authorized personnel.
• Checkthatthedoordoesnotleak.
• Checkthedrainvalveandremoveanyuff.
• Inspecttheinteriorofthemachine(duringanactualwashcycletoen-
sure that no leaks are noticed) by:
- Turning of the main power switch of the machine.
- Remove the top cover and the protective front and rear plates.
Preventive maintenance

Related product manuals