Page 7
Adapta Valve Installation - Part# 560070
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.Step 11
Step 12 Attach the
adapt-a-valve as illustrated in the three photos above, choosing the configuration
that fits your plumbing. (When attaching the adapt-a-valve to straight pipe threads, use Teflon
tape on the threads.)
Caution: Water
supply line to the system must be from the cold water supply line only. Hot
water will severely damage your system.
Configuration for 3/8”
compression fittings
Configuration for 1/2”
compression fittings
Hot
Supply
Cold
Supply
Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes
Drain Saddle Installation - Part# 164016
Step 13
Step 14
Step 15 Drill a ¼” hole through the drain pipe at least 1 ½” above the nut of the
P-trap
to allow for the removal of the P-trap if necessary. Assemble
the drain saddle around the drain pipe while positioning the drain
saddle connection over the drilled 1/4” hole. Insert screw driver into
the opening of the drain saddle and align with drilled hole in drain
pipe. Using Phillips screw driver tighten screws evenly and securely
on both sides of the drain saddle. Attach black compression nut, but
do not tighten at this time.
The small square black foam gasket with a circle cut out of the middle
must be applied to the inside of the drain saddle. Remove sticky tape
backing and stick to the drain saddle as shown.
1 Black compression nut
1 Semicircle bracket with opening
2 Screws 1 Foam gasket
2 Nuts for screws 1 Semicircle bracket
Gather the pieces of the drain saddle
Caution:
Do not over tighten the screws. It may crack the drain saddle.
If you have a garbage disposal, do not install the drain line near it. Installation
of the drain line must be either above the disposal, or if a second sink drain
is available, install it above the cross bar on the second sink. Installation of
the drain line near a garbage disposal may cause the drain line to plug. If no
other installation of drain line is available, Watts offers drain line installation
kits (part numbers 164014 and 164020) that can be used with garbage
disposals.
Caution: