415 RO FILTRATION PROCESS
SPECIFICATIONS:
1st stage: Sediment lter, 5 micron, 10”
2nd stage: Carbon block lter, 5 micron, 10”
3rd stage: TFC membrane, 50GPD @ 60PSI
Auto shut off valve
Operating pressure: 40-100 PSI
Operating temperature: 40-100°F
Please contact your local dealer at:
REPLACEMENT PARTS
WATTS ITEM# DESCRIPTIONS SERVICE LIFE
IF-SP-1005 Sediment lter, 5 micron, 10” 6-12 months
F109009 Carbon block lter, 5 micron, 10” 6-12 months
W-1812-50 TFC membrane, 50GPD @ 60 PSI 24-36 months
W560033 Inline carbon lter 12-18 months
4th stage: Inline carbon lter