Technical Data
www.webasto.us Webasto Product N.A., Inc. www.techwebasto.com
25
5. Technical Data
The following data is subject to the normal tolerance for heaters, if no tolerance is specified. This is approximately +/-10%
in an ambient of 20 °C at nominal voltage.
Heater DBW 2010
Design Coolant heater with high pressure nozzle
Heat output BTU/hr. (kW) 45,000 (13.1)
Fuel Diesel #1, Diesel #2 and Arctic
Fuel Consumption l/hr. (gal/hr.) 1.5 (0.4)
Rated Voltage (V) 12
Operating Voltage (V) 10-14
Power Consumption w/o water pump (W) 60
Permissible ambient temperature during operation °C (°F) -40...+60 (-40...+140)
Storage temperature °C (°F) +85 max. (185 max.)
Min. capacity of cooling system l (gal) 10 (2.6)
Permissible operating pressure of coolant bar (psi) 0.4 -2 (06 - 29)
CO in exhaust gas ppm 32
CO
2
in exhaust gas % by volume 10 ± 0.5
NO
x
in exhaust gas ppm 70
HC in exhaust gas ppm < 5
Emission Bacharach 1
Dimension of
L
Heater
W
mm (inch)
H
584 (23)
205 (8.1)
228 (9)
Dimension of
L
Tray Mount
W
mm (inch)
H
610 (24)
254 (10)
300 (11.75)
Weight on Tray (lb) 21.5 (65)
Weight of heater including control unit kg (lb) 15 (33)
Water pump U4846 (Magnetic Drive)
Flow rate l/hr. (gal/min) 1650 (7) against 0.15 bar
Rated voltage (V) 12
Power Consumption (W) 28
Dimensions
L
mm (inch)
W
H
128 (7.16)
94 (3.70)
82 (3.23)
Weight kg (lb) 0.85 (1.88)
Hose Connections mm (inch) 20 (0.78)