EasyManua.ls Logo

Webasto Thermo Top - User Manual

Webasto Thermo Top
47 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Thermo Top
Tele Thermo Top
ab Serien-Nr. 300 000/från och med serienr 300 000
from serial no. 300 000 onward
Thermo Top T
Tele Thermo Top T
ab Serien-Nr. 300 000/från och med serienr 300 000
from serial no. 300 000 onward
Stand-Zuheizung
Auxiliary Heater
stånd-tillsatsuppvärmning
Typ BW50 (Benzin/Petrol/Bensin)
Typ DW50 (Diesel)
Die Betriebsanweisung vor Inbetriebnahme
des Heizgerätes unbedingt lesen.
Operating Instructions must be read before
attempting to start up the heater.
Läs noga igenom denna bruksanvisning innan du
använder värmeaggregatet första gången
08/2000
Wasser-Heizgeräte Einbauanweisung
Water Heater Installation instructions
Vattenvärmeaggregat Monteringsanvisning

Questions and Answers

  • E
    Edwin WalkerAug 6, 2025
    Why does my Webasto Thermo Top Water Heater operate for only a few minutes?
    • S
      Steven ClarkAug 6, 2025
      If your Webasto Water Heater operates only for a few minutes, consider these potential causes: * The heater might not be seated properly in its support, causing exhaust gas to be aspirated. Loosen the 2 M6 screws and position it correctly. * The fuel lines of the heater might not be properly connected, with flow and return pipes interchanged. Connect the fuel lines in accordance with the installation instructions. * A kinked coolant hose or a cooling system that hasn't been bled completely. Check the line routing and bleed the cooling system, starting the engine.
  • T
    Tyler HoustonAug 10, 2025
    What to do if Webasto Thermo Top Water Heater fails to ignite but the fan motor is operating?
    • D
      dustinbakerAug 11, 2025
      If your Webasto Water Heater fan motor is operating but the heater fails to ignite, the intermediate fuel reservoir may be empty. Allow the vehicle engine to run for approximately 30 seconds.
  • B
    bradleycarrollAug 16, 2025
    What to do if vehicle fan fails to switch on in Webasto Water Heater?
    • M
      Mary AdkinsAug 16, 2025
      If the vehicle fan fails to switch on when the threshold temperature (>30° of coolant) is reached in your Webasto Water Heater, a defective fuse F3 could be the cause. Replace the fuse.
  • R
    Robert LutzAug 21, 2025
    What to do if Webasto Thermo Top emits blue smoke or soot?
    • R
      Ronald VangAug 21, 2025
      If you notice blue smoke or soot in the exhaust gas, or if the Webasto Water Heater is emitting smoke, it could be due to: * A kinked or blocked suction or exhaust gas line. Check the lines for unobstructed passage. * An installation fault, where the heater is not properly seated in its support, or the gasket of the exhaust gas pipe was not installed. Check the installation.
  • M
    Michael MartinezAug 26, 2025
    Why is my Webasto Thermo Top heat output insufficient?
    • K
      kyatesAug 26, 2025
      If your Webasto Water Heater isn't providing enough heat, make sure the heater control lever is set to 'warm' and the fan switch is set to a higher setting. The heater control lever or vehicle fan may be incorrectly set.
  • H
    Heather TylerOct 31, 2025
    How to troubleshoot Webasto Thermo Top Water Heater that can't be switched on?
    • A
      Allen MartinOct 31, 2025
      If your Webasto Water Heater won't switch on, several issues could be the cause. It might be in overheating lock-out mode, in which case you should remove the 15A fuse and determine the cause. Check that the summer/winter switch is in the correct position and that the battery isn't discharged (charge it if it is). A defective fuse could also be the reason, so replace it if necessary. If it's a defective digital timer, use a testing device on the heater to check if the digital timer switches properly. Disconnect connector X14 from the heater, connect the testing device, and switch on the digital timer. The indicator lamp must light up; if not, the timer is defective and the power supply to the timer is disrupted. Alternatively, check if 12 V voltage is present across contact 1 (6-pole conne...

Summary

Installation Instructions Overview

Legal Provisions for Installation

StVZO Compliance and Approvals

Details on StVZO regulations, design approval numbers, and certification requirements.

Installation Location

Connection to the Vehicle Cooling System

Venting and Overheating Prevention

Importance of proper venting to prevent overheating issues.

Installation Example

Passenger Car Installation Diagram

Illustrates the installation of Thermo Top in a passenger car with numbered components.

Fuel and Air Systems

Fuel Supply Circuit Installation

Details fuel supply integration for carburetor and injection engines.

Combustion Air Supply

Instructions for drawing combustion air from a cool, splash-proof location.

Electrical and Control Connections

Heater and Timer Electrical Connections

Covers control unit, heater, and digital timer electrical connections.

Wiring Diagram Legend

Wiring Diagram Symbols and Designations

Lists positions, designations, and remarks for wiring components.

Automatic Control Wiring Diagram

Wiring Diagram Layout

Visual representation of automatic control for Thermo Top and Digital Timer.

Operation and Malfunctions

Heater Shut-Down Causes

Explains shut-down due to malfunctions, overheating, undervoltage, or overvoltage.

Troubleshooting Guide

Heater Not Switching On

Troubleshooting steps for when the heater cannot be switched on.

Ignition and Operation Issues

Addresses problems with ignition, short operation, and insufficient heat output.