Testing Alarm Banks
By default, the LS-350 checks the phone lines serving the elevators every 12 hours.
However, if you need to test the alarm immediately, use the Enable Inspection button in
the Line Monitoring section. This will prompt the LS-350 to check the connected phone
lines every minute.
To test the alarm:
1. Go to the Line Monitoring section.
2. Tap Enable Inspection.
The alarm will be triggered if the phone fails to check in or if the line is disconnected within
one minute.
Elevator Phone Setup [MWP-150 / MWP-302]
MWP-150
o LS-350-01
Function 1 Primary Phone Number
288XX##### [XX = to station number the phone is connected to]
Function 3 Secundary Phone Number
289XX##### [XX = to station number the phone is connected to]
Function 12 Self Diagnostics
1
Function 13 Lobby Station
1
Function 15 Autocheck Number
400XX [XX = to station number the phone is connected to]
Note: The LS-350-01 managers all the calls. In this setup, each elevator phone first reaches out to the LS-
350 and then, the system dials according to what is set under the Unit Mode Configuration.
o LS-350-10
Function 1 Primary Phone Number
Enter primary phone number
Function 3 Secundary Phone Number
Enter Secundary phone number
Function 12 Self Diagnostics
3
Function 13 Lobby Station
1
MWP-302
o LS-350-01
Function 1 Primary Phone Number
288XX [XX = to station number the phone is connected to]
Function 3 Secundary Phone Number
289XX [XX = to station number the phone is connected to]
Function 12 Self Diagnostics
1
Function 13 Lobby Station
1
Function 15 Autocheck Number
400XX [XX = to station number the phone is connected to]
Note: The LS-350-01 managers all the calls. In this setup, each elevator phone first reaches out to the LS-
350 and then, the system dials according to what is set under the Unit Mode Configuration.