WECO 5K3-XP-EMEA
73
3.4 High Voltage Module Configuration
ATTENTION: The High Voltage mode mandates that the Battery Modules must be connected in series.
ATTENTION: The following table provides the possible module configurations. NO OTHER
configurations are suitable.
ATTENTION: Before connecting an HV inverter with the HV BOX terminal, always check the
Inverter Input range. ( Min and Max Voltage)
ATTENTION: a serial connection cluster is efficient only if all battery modules are individually
fully charged in LOW VOLTAGE, this process will allow a proper equalization between modules
of the same cluster. The HV string preparation is an important step of the commissioning of an
HV system, the installation of an HV system must include the equalization of the tower before
delivering to the end user
5K3-XP HV Box Type A 80-750Vdc + HV Inverter
( always check the Operational Voltage range of the inverter)
ATTENTION>
(*)Yellow Marked Voltage Range are possible only with the ``Type B HV BOX``
that has a voltage input starting from 150V up to 1000Vdc
ATTENTION
For the calculation of the energy of a cluster (in both LV and HV systems) the nominal capacity of a
battery is generally counted in 5.2kWh as a result of the multiple connection discrepancies, and
imbalances between batteries
To ensure the maximum energy available from the HV SYSTEM it is important to calibrate each single module before
connecting in series.
Each module shall be charged from the LV terminals up to 100%