The programming the doses of the left-hand push button panel rst automatically programs the doses of
the right-hand push button panel. It is, however, both possible and advisable to program the push button
panels independently, taking care to always start from the left-hand push button panel.
8.1 PROGRAMMING COFFEE DOSES
move the programming lever (X) located under the machine's boiler cover to ON;
insert a pod in the filter holder and attach it to the group, tightening it firmly;
place the cup under the dispenser spout;
press the STOP/PROG key (G) for approx. 5 seconds: all the dose button LEDs
will turn on;
press the desired dose key, example (C) ;
once the desired dose is reached, confirm by pressing the STOP/PROG key (G) ;
repeat the operation for the other dose keys;
to exit programming, press the STOP/PROG key (G) or wait 30 seconds;
when programming is complete, return the programming lever (X) to the OFF position.
8. PROGRAMMING
The programming operations must be performed by technical personnel.
The programming of each dose must be done with a new pod and not with previously used pods.
The maximum programmable time is 120 seconds
.
G
G
CC
X
O
N