8.4 LOADING DEFAULT DATA
Proceed as follows to restore the factory settings:
Move the programming lever (X) located under the machine’s boiler cover to ON;
turn on the machine and hold down the keys (A) (C) and (E) for at least 5 seconds;
when programming is complete, return the programming lever (X) to the OFF position.
8.2 PROGRAMMING THE AUTOSTEAMER TEMPERATURE FOR HOT MILK
Move the programming lever (X) located under the machine’s boiler cover to ON;
turn on the machine, holding down the (B) button for at least 3 seconds;
the flashing of the leds on keys (A) and (B) indicates the set temperature, in particular:
- the (A) button indicates tens;
- the (B) button indicates units;
to increase or decrease the temperature by 1°C at a time, using the (A) + and (B) - keys;
to confirm the new set temperature, press the STOP/PROG key (E) for at least 3 seconds.
8.3 PROGRAMMING THE AUTOSTEAMER TEMPERATURE FOR FOAMY HOT MILK
Turn on the machine, holding down the (A) button for at least 3 seconds;
proceed as indicated in paragraph 8.2 .
All programming operations must be made by quali ed technical personnel.
Take care when accessing the inside of the machine to set the programming lever: some of the
components are scalding hot and there are parts under electrical tension.