Document P/N: 2A43495
Release Date: 02/27/2018
Revision: IR
13 of 16
Relief tolerance of +/- 5% to rated disc pressure
Suitable for pumping operations at no more than 90% of the marked burst pressure without reduction in service
life.
Operating above that range will introduce fatigue to the disc reducing functional life of the product and it may
result in premature rupture of the disc.
Flow rate capability (@ 42/fps):
WARNING
RUPTURE DISC MAY FRACTURE UPON ACTIVATION. USERS MUST TAKE PRECAUTIONS TO ENSURE
THAT THE EXL PRESSURE RELIEF DEVICE IS ORIENTED SUCH THAT PERSONNEL OR EQUIPMENT
ARE NOT IN LINE OF THE DISCHARGE OUTLET.
WARNING
NEVER BLOCK THE DISCHARGE OUTLET OF THE EXL PRESSURE RELIEF DEVICE.