EasyManuals Logo

Weir SPM User Manual

Weir SPM
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Document P/N: 2A43495
Release Date: 02/27/2018
Revision: IR
15 of 16
WARNING: DISASSEMBLY UNDER PRESSURE CAN CAUSE SERIOUS BODILY INJURY, DEATH,
OR PROPERTY DAMAGE.
Always Remember:
1. Always wear PPE (personal protective equipment).
2. Only qualified technicians should perform maintenance on SPM
®
products.
3. Always use SPM
®
supplied new parts kit for reassembly.
4. Clean all components thoroughly prior to reassembly.
5. Check sealing surface area for pitting, erosion or other flaws.
6. Use only SPM
®
parts on SPM
®
products.
7. This device is intended to discharge atmospherically when it relieves.
Maintenance Requirements:
Weir recommends that the rupture disc be removed from service after 250 working hours or 100 stages,
whichever comes first.
Vessel Test Procedures:
Prior to shipment, product testing procedure 4S12497 requires that each rupture disc body pass a one-time
vessel test at 150% it’s rated working pressure; then, when conducting subsequent vessel tests on used
housings, limit the pressure to 100% of rated working pressure as required by 4S12497.
Housings should always be vessel tested in accordance with product testing procedure 4S12497. Utilize the
correct dummy seat for the appropriate size (2" - 2P42526, 3" - 2P42280). During the vessel testing the O-
ring and hex nut shall be used.
SECTION IV: Maintenance and Re
p
ai
r
Dummy Seat
2" - 2P42526
3" - 2P42280

Other manuals for Weir SPM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weir SPM and is the answer not in the manual?

Weir SPM Specifications

General IconGeneral
BrandWeir
ModelSPM
CategoryControl Unit
LanguageEnglish

Related product manuals