Installation and operating instruction
Fieldbus module EM3/2
7 Technical documentation
83296302 1/2018-01 La
25-32
Index Bit Information Description S
72 0…15 Operating hours counter oil
stage 2 in seconds (fixed)
Lowbyte 32-Bit operating hours counter X
73 0…15 Operating hours counter oil
stage 2 in seconds (fixed)
Highbyte 32-Bit operating hours counter X
74 0…15 not used – –
75 0…15 Actual degree of modulation 16-Bit actual degree of modulation X
76 0…15 Actual position of air actuator 16-Bit actual position of air actuator 0
77 0…15 Actual position of Gas actuator 16-Bit actual position of gas actuator 0
78 0…15 Start-up counter oil and gas
(can be reset)
Lowbyte 32-Bit start-up counter X
79 0…15 Start-up counter oil and gas
(can be reset)
Highbyte 32-Bit start-up counter X
80 0…15 Operating hours counter oil and
gas in seconds (can be reset)
Lowbyte 32-Bit operating hours counter X
81 0…15 Operating hours counter oil and
gas in seconds (can be reset)
Highbyte 32-Bit operating hours counter X
82 0…15 Lifetime counter in seconds Lowbyte 32-Bit time counter X
83 0…15 Lifetime counter in seconds Highbyte 32-Bit time counter X
84 0…15 Fuel quantity meter Lowbyte 32-Bit quantity meter X
85 0…15 Fuel quantity meter Highbyte 32-Bit quantity meter X
86 0…15 not used – X
87 0…7 Item number SW P1 Byte 0 (Lowbyte) 24 Bit item number X
8…15 Item number SW P1 Byte 1 24-Bit item number X
88 0…7 Item number SW P1 Byte 2 (Highbyte) 24 Bit item number X
8…15 Index item number SW P1 – X
89 0…7 Combustion manager produc-
tion day
– X
8…15 Combustion manager produc-
tion month
– X
90 0…7 Combustion manager produc-
tion year
– X
8…15 not used – X
91 0…7 Device number Byte 0 (Lowbyte) 32 Bit device number X
8…15 Device number Byte 1 32-Bit device number X
92 0…7 Device number Byte 2 32-Bit device number X
8…15 Device number Byte 3 (Highbyte) 32 Bit device number X
93 0…7 Item number HW Byte 0 (Lowbyte) 24 Bit item number X
8…15 Item number HW Byte 1 24-Bit item number X
94 0…7 Item number HW Byte 2 (Highbyte) 24 Bit item number X
8…15 Index item number HW – X
95 0…7 Device item number Byte 0 (Lowbyte) 24 Bit item number X
8…15 Device item number Byte 1 24-Bit item number X
96 0…7 Device item number Byte 2 (Highbyte) 24 Bit item number X
8…15 Index item number device – X
97 0…7 Item number SW EM Byte 0 (Lowbyte) 24 Bit item number X
8…15 Item number SW EM Byte 1 24-Bit item number X
98 0…7 Item number SW EM Byte 2 (Highbyte) 24 Bit item number X
8…15 Index item number SW EM – X