EasyManua.ls Logo

WEISS HP140 - Connection Diagram for Control Cables

WEISS HP140
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WAS.handling Electro Documentation 24
3.5 Connection Diagram for control cables
3.5.1 CAN-Bus – without I/O-Module
The drive controls will be connected to each other with the preconfigured cable 563-200000200. Terminal
resistors are inside the plugs.
3.5.2 CAN-Bus – with one I/O-Module
Both drive controls and the I/O-Module will be connected together via cable 563-200000202. In the plug at the
end of the line, a terminal resistor is integrated. Onto the I/O-Module, the bridge ‘Term’ has to be wired.
3.5.3 CAN-Bus – two of I/O-Modules
At the version with two I/O-Modules and two drive controls, the cable 563-200000204 has to be used. The
Wiring is similar as with one I/O-Module, but the bridge “TERM” is necessary only at the end of the line.
Clamp Function
Pin 1 Bridge
Pin 2 Bridge
Pin 3 n.c.
Pin 4 n.c.
Pin 5 n.c.
Pin 6 n.c.
Pin 7 CAN – H
Pin 8 CAN – GND
Pin 9 CAN – L
Pin 10 Shield (black)
Pin 11 GND
Pin 12 +24V Supply
CAN-Adresses:
Slot PLC: “0A“
Plug-In Module AC110: “1B“
CAN-Adresses:
Slot PLC: “0A“
Plug-In Module AC110: “1B“
I/O – Module 1: “CC“
I/O – Module 2: “CD“