EMERGENCY STOP:
Suitable protective devices in accordance with EN 60204 Part 1 must be used.
Danger!
Adequate protective devices, e.g. covers, protective grids, light curtains or
step sensors must be installed for operation in order to protect the operating
personnel from injury by the rotary indexing table.
In the case of an EMERGENCY STOP the motor line must be reliably interrupted in order to stop the supply of energy and
to ensure protection against unintentional re-starting. Interruption of the terminal “2“ (RESET) alone is not sufficient, as
these terminals require a functioning circuit.
In the case of an EMERGENCY STOP, interrupt the following lines:
- Motor line between the contactor and the motor
- Terminal “2“ (RESET/STOP) on the control card
Designated use:
This device is designed for industrial and commercial systems and conforms to the valid standards and regulations. All of
the instructions regarding technical data and the permissible conditions at the place of installation must be observed.
This device is a component for installation in machines. Start-up (start of designated operation) is not permitted until it
has been established that the machine is in conformance with the EMC directive 89/336/EEC and the end product is in
conformance with the machinery directive 89/37/EC.