Derrick OwenSep 7, 2025
What to do if my Welch Allyn Medical Equipment displays 'Internal malfunction'?
- SSarah TaylorSep 7, 2025
If your Welch Allyn Medical Equipment displays an internal malfunction, contact Technical Service for assistance.
What to do if my Welch Allyn Medical Equipment displays 'Internal malfunction'?
If your Welch Allyn Medical Equipment displays an internal malfunction, contact Technical Service for assistance.
What happens if cuff pressure duration exceeded on Welch Allyn Spot Vital Signs LXi Medical Equipment?
If the Welch Allyn Medical Equipment exceeds cuff pressure duration, the device will power down.
What happens if cuff pressure limits exceeded on Welch Allyn Medical Equipment?
If the Welch Allyn Medical Equipment exceeds cuff pressure limits, the device will power down.
What to do if blood pressure reading cancelled by user on Welch Allyn Medical Equipment?
If the Welch Allyn Medical Equipment displays a blood pressure reading cancelled by user, retake the blood pressure reading.
What to do if Welch Allyn Spot Vital Signs LXi Medical Equipment shows probe data error?
If the Welch Allyn Medical Equipment displays a probe data error, retake the reading. If the problem persists, replace the probe.
How to fix device outside operating temperature range on Welch Allyn Medical Equipment?
If the Welch Allyn Medical Equipment is outside the operating temperature range, change the ambient temperature.
What to do if Welch Allyn Medical Equipment shows internal SpO error?
If the Welch Allyn Medical Equipment displays an internal SpO error, retake the reading.
What to do if Welch Allyn Medical Equipment shows probe heater error?
If the Welch Allyn Medical Equipment displays probe heater error, retake the reading. If the problem persists, replace the probe.
What to do if Welch Allyn Spot Vital Signs LXi shows internal temperature malfunction?
If the Welch Allyn Medical Equipment displays an internal temperature malfunction, retake the temperature. If the problem persists, contact Technical Service.
How to fix broken thermometer probe on Welch Allyn Spot Vital Signs LXi?
If the Welch Allyn Medical Equipment displays a broken thermometer probe, replace the probe.
Display Type | LCD |
---|---|
Blood Pressure Measurement Method | Oscillometric |
NIBP Technology | Oscillometric |
MAP Calculation | Yes |
Battery Type | Rechargeable Lithium-Ion |
Device Type | Vital Signs Monitor |
Brand | Welch Allyn |
Model | Spot Vital Signs LXi |
Measurements | Blood Pressure, Pulse Rate, SpO2, Temperature |
Pulse Rate Range | 30 bpm |
Blood Pressure Range | Systolic: 60-250 mmHg |
Power Source | AC Power, Rechargeable Battery |
Wireless Connectivity | Bluetooth |
Memory | Up to 50 |
Battery Life | Approximately 8 hours |
Connectivity | USB |