Cod.006.0001.1440
03/06/2013 v2.2
ENGLISH
0
17/28
Tab. 5 - Special functions in MMA mode
11.2 DC TIG WELDING
Use this button to select one of the following welding modes:
Use this button to select one of the following torch trigger procedures:
DC TIG PARAMETERS SETTING (1ST LEVEL) 11.2.1
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
Tab. 6 - 1st level menu parameters in DC TIG mode
*1: This parameter is set as a percentage referred to the value of the following parameter: WELDING CURRENT
*2: The value of this parameter can be set as a percentage of the welding current or as an absolute value expressed in Amperes.
*3: SYN: This code indicates that parameters control is synergic. The optimal value of this parameter is set automatically by the microprocessor
on the basis of the preset welding current value. This value can be displayed but it is not user-adjustable.
*4: Available when "KIND OF PULSE" parameter= FAST
*5: Available when "KIND OF PULSE" parameter= SLOW
DC TIG PARAMETERS SETTING (2ND LEVEL) 11.2.2
Access the 2nd level menu by holding the button down for 3 seconds.
The message appears on the following displays: D1
L.2= LEVEL.2= 2ND LEVEL MENU
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
Tab. 7 - 2nd level menu parameters in DC TIG mode