Maintenance (Continued)
SELF-DIAGNOSTIC CODES
(See Table 1)
SPRING REPLACEMENT
(See Figure 10)
There are two springs on the rear of condensate water tank guide.
1. Release the screw on the spring hook.
2. Take off the spring hook, and then pull out the opposite spring
hook from hole in the condensate water tank guide.
3. Replace with a new spring in reverse order.
4. Repeat this cycle for the other spring.
The alarm light is activated if abnormal operation occurs, and a code is displayed on the control panel.
The compressor and condenser fan motor will stop operating. The evaporator fan will continue to run for 3 minutes.
If the fault is rectified within 3 minutes, the unit will resume operation. If the fault persists for more than 3 minutes,
the evaporator fan also stops. The fault must be rectified before the unit can resume normal operation.