15
USING THE GENERATOR
CAUTION: The generator can run at its surge wattage capacity for only a short time. Connect electrical devices
requiring a rated (running) wattage equal to or less than the rated wattage of the generator. Never connect devices
requiring a rated wattage equal to the surge wattage of the generator. This can trip the circuit protectors (circuit
breakers).
Tool or Appliance Rated (Running) Watts ADDITIONAL SURGE WATTS
Electric water heater (40 Gal) 4000 0
Hot plate 2500 0
Saw - radial arm 2000 2000
Electric stove (each element) 1500-2800 0
Saw - circular 1500 1500
Air compressor (1 HP) 1500 3000
Window air conditioner 1200 1800
Saw - miter 1200 1200
Microwave 1000 0
Well water pump 1000 1000
Saw - reciprocating 960 1040
Sump pump 800 1200
Refrigerator freezer 800 1200
Furnace blower 800 1300
Computer 800 0
Electric drill 600 900
Television 500 0
Deep freezer 500 500
Garage door opener 480 0
Stereo 400 0
Box fan 300 600
Clock radio 300 0
Security system 180 0
DVD player / VCR 100 0
Common light bulb 75 0
Note: The above wattage figures are estimates. Check the wattage listed on the electrical device before consulting
this chart. Once the electrical devices that will be powered by the generator have been determined, connect these
devices according to the following procedure:
1. Plug in each electrical device, making sure that the device is turned off.
2. Check the overload light and power indicator light. If the overload light is on, remove the plugged in load, then
press the power reset button before plugging the loads back in. If the reset button does not reset, wait several min-
utes and try again. If the power light still does not come on, call the customer service number for further instruc-
tions.
Figure 7- Estimated wattage requirements of common electrical devices