28
▼ Light control + timer control interface
Press or to choose load control mode. When the inverse cursor
rests on Light On + Timer in the load control interface, press to enter into
light control plus time control interface.
When press or , the inverse cursor moves among every
parameters. When is continuously pressed, it moves back to main menu
interface and press or to modify every parameters. Only when
the inverse cursor rests on“Work Time” interface, can modification of the parameters be
saved. When modification is confirmed, press ,and the following picture
appears. Press or to choose save confirmation or save
cancellation. After choosing confirmation,
Press again, and the modified parameter can be saved or cancelled. When
save cancellation is chosen, the inverse cursor moves back to the main menu interface.
Light Timer Control
On : 06.0 V Delay :10 m
Off : 05.0 V Delay :10 m
Work Time : 10 : 00 : 00
ENTER/
→
Light Timer Control
On : 05.0 V Delay :10 m
Off : 06.0 V Delay :10 m
Work Time : 10 : 00 : 00
↑/ +
↓/ -
ENTER/
→
Save Cancel
MENU/←
MENU/
←
ENTER/
→
↑/ +
↓/ -
↑/ +
↓/ -
ENTER/
→