ENGINE
TROUBLESHOOTING
Introduction
The tables which follow indicate troubleshooting procedures based upon
certain
problem indicators, the
probable
causes
of the problems,
and
the recommendations
to
overcome
these
problems.
Note
that
the engine's control system (electrical system) is protected by a
2O-Ampere
manual
reset
circuit
breaker located on the rear lifting bracket
problem
Key
switch
ON
but
no
panel
or
test function.
PREHEAT
switch is de-
pressed:
no preheat
solenoid activation:
no electric
fuel
pump or
alternator excitation.
probable Calise
1. Battery OFF.
2.
20
Amp circuit
breaker is
tripped.
3.
Loose
battery
cable connection
1. Faulty solenoid,
connections or switch.
2.
Faulty connection
or
tripped
10
Amp breaker
on the I terminal on the
preheat solenoid.
~
WESTERBEKE
Engines & Generators
46
yerificatjonffiemedy
1. Tum Battery ON.
2.
Reset
the breaker
by pushing
in
the
button.
3. Check the + connection
to the starter
and
the -
connection to the
ground
stud on the bell
housing.
1.
Connection for
12
volts at
.
S terminal of the
solenoid
is.
faulty.
1.
Check the preheat
switch.
2.
Check for
12
volts
at
the
10
Amp breaker.
Check
for
12
volts at the R
terminal
on the alternator
when
the
the preheat button
is
pushed.