Installation
Start-Up
Maintenance
Parts
Warranty
This manual must only be used by a qualied installer / service technician. Read all instructions in this manual before installing.
Perform steps in the given order. Failure to do so could result in substantial property damage, severe personal injury, or death.
The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for
typographical errors in literature.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
whl-035 Rev. 002 Rel. 002 Date 11.1.17
The surfaces of these products contacted by potable (consumable) water contain less than 0.25% lead by weight as required
by the Safe Drinking Water Act, Section 1417.
Use and Care Manual
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
Light Duty Commercial
Electric Water Heaters

Questions and Answers

  • A
    Adam GregoryAug 6, 2025
    How to fix a Westinghouse Water Heater with no hot water?
    • A
      Aaron PenaAug 7, 2025
      If your Westinghouse Water Heater has no hot water, first check if the manual disconnect switch is turned off and turn it on. Also, check for a blown fuse or tripped circuit breaker and replace the fuse or reset the breaker. Another potential cause is shorted or improper wiring, in which case you should replace, repair, or rewire as needed. An overloaded circuit could also be the cause, so provide an adequate circuit to reduce the load. Lastly, a grounded element or thermostat could be the issue, and you should replace it.
  • S
    Shawn WolfeAug 11, 2025
    Why is my Westinghouse WEC100C2X045 not producing enough hot water?
    • M
      Mary NormanAug 11, 2025
      If your Westinghouse Water Heater isn't producing enough hot water, it might be undersized for your needs; try reducing the rate of hot water usage. Another cause may be defective element(s), in which case you should check the amperage and replace the element if it's low. Finally, a miswired or defective thermostat could be causing only one element to work, so check the wiring or replace the thermostat.
  • J
    Jonathan SimonAug 17, 2025
    Why is the water from my Westinghouse WEC100C2X045 too hot or not hot enough?
    • D
      Daniel StewartAug 17, 2025
      If the water from your Westinghouse Water Heater is either too hot or not hot enough, the thermostat setting may be too high or low; change the setting as required. A thermostat out of calibration can also cause this issue, so replace the thermostat. Inspect the thermostat access panel(s) and/or insulation and replace as needed. Finally, ensure that the retaining spring(s) or mounting screws hold the thermostat(s) tightly to the mounting plates.
  • L
    Lisa BoydAug 21, 2025
    What to do if my Westinghouse Water Heater is leaking?
    • H
      Heidi JonesAug 21, 2025
      If your Westinghouse Water Heater is leaking, start by checking for loose connections between the inlet/outlet piping, relief valve, and/or hex nut union on the tank fittings and tighten them. If that's not the issue, inspect the seal ring washer and replace the seal rings as required. Also, examine the gasket around the heating element(s) and replace the gasket if necessary.
  • N
    Noah PopeAug 27, 2025
    What to do if the T&P valve on my Westinghouse WEC100C2X045 Water Heater discharges?
    • A
      Adriana WongAug 27, 2025
      If the T&P valve on your Westinghouse Water Heater is discharging, first try opening and closing the handle to reseat the valve. If the issue persists, thermal expansion in a closed water system may be the cause, in which case you should install a thermal expansion tank. If the valve is damaged or defective, replace the relief valve. Note: Do NOT plug the T&P valve under any circumstances.
  • D
    Debra CarterSep 1, 2025
    Why does my Westinghouse WEC100C2X045 Water Heater have a hot water odor?
    • T
      Todd SmithSep 1, 2025
      If your Westinghouse Water Heater has a hot water odor, it may be due to high sulfate or mineral content in the water supply; drain and flush the water heater, then refill it. If the odor persists, bacteria in the water supply could be the cause. In this case, you should check with a local water treatment specialist or utility to identify and address the problem.

Westinghouse WEC100C2X045 Specifications

General IconGeneral
BrandWestinghouse
ModelWEC100C2X045
TypeElectric Water Heater
Capacity100 Gallons
Voltage240 V
Wattage4500 W
Energy Factor0.95