7
General
704 67 020 00 _ 111
OPERATING INSTRUCTIONSGF Robimat XL / XM
Type (Standard specication for climate
class N)
Robimat XL Robimat XM
Selections max. 72 (9 products; 8 shelves) max. 56 (7 products; 8 shelves)
Product compartments max. 24 (3 product compartments
per shelf)
max. 24 (3 product compartments
per shelf)
Height 1,830 mm 1,830 mm
Width 1,130 mm 990 mm
Depth 880 mm 880 mm
Weight approx. 360 kg approx. 300 kg
Electrical data 220-230 V; 50/60Hz; min. 10 A 220-230 V; 50/60Hz; min. 10 A
Power consumption max. 750 W max. 750 W
Max. sound pressure level < 70 dB (A) < 70 dB (A)
Ambient temperature (machines with
standard chiller unit)
+16°C to +32°C
Ambient temperature (outdoor with heater) -20°C to +32°C
Weight and power consumption are standard values. The weight may vary depending on optional features.
In addition to the chiller unit a heater is tted in the outdoor machine. The heater cannot be switched on manually. If
the ambient temperature on site falls below 0 °C, the heater is switched on by the vending machine control board. In
this way the interior is kept frost-free.
Climate class Siela version Robimat XL Robimat XM
N (Normal) Standard SKA 435 SKA 435
More powerful SKA 751 / SKA 790 SKA 751 / SKA 790
LM - -
SKA 435 400 W 220 g (R134a)
SKA 751 650 W 330 g (R134a)
SKA 790 650 W 250 g (R744)
SKA 790: maximum permissible air humidity: 65%
Climate class N (normal): Ambient temperature +16 to +32°C
Climate class ST (subtropical): Ambient temperature +16 to +38°C
Climate class T (tropical): Ambient temperature +16 to +43°C
The coolant used in all chiller units is R 134a.
Information regarding regulation (EU) no. 517/2014
Contains uorinated greenhouse gas HFKW-134a in hermetically sealed equipment.
Chiller unit HFKW-134a
[kg]
GWP CO2-equivalent
[t]
SKA 435 0.220 1430 0.314
SKA 751 0.330 1430 0.471