WD-151E - WD-421E Rev. 00 (202310)
Technical specifications touch
64
5. Technical specifications
The manufacturer reserves the right to make changes to the technical data.
* Adjust where necessary. Affects the capacity and connected power.
** Option
TECHNICAL DATA
Pump motor, pre-wash (kW), WD-211E - WD-421E 1.5
Pump motor, chemical wash 1 (kW) 1.5
Pump motor, chemical wash 2 (kW), WD-331E - WD-421E 1.5
Pump motor, chemical wash 3 (kW), WD-421E 1.5
Pump motor, recirculating rinse (kW) 0.11
Booster pump (kW) ** 0.58
Heat recovery fan (kW) 0.12
Drive motor (kW) 0.12
Booster heater 1 (kW), WD-151E 9 *
Booster heater 1 (kW), WD-211E - WD-421E 12 *
Booster heater 2 (kW), WD-151E 9
Booster heater 2 (kW), WD-211E - WD-421E 12
Tank heater, chemical wash 1 (kW), WD-151E - WD-241E 12
Tank heater, chemical wash 1 (kW), WD-331E - WD-421E 9
Tank heater, chemical wash 2 (kW), WD-331E - WD-421E 9
Tank heater, chemical wash 3 (kW), WD-421E 9
Heat recovery, cooling surface (m²) 25
Heat recovery fan, flow (m³/hour) 100
Tank volume, pre-wash (litres), WD-211E 51
Pump motor, pre-wash (litres), WD-241E - WD-421E 77
Tank volume, chemical wash tank 1 (litres) 100
Tank volume, chemical wash tank 2 (litres), WD-331E - WD-421E 100
Tank volume, chemical wash tank 3 (litres), WD-421E 100
Tank volume, final rinse tank (litres) 6
Weight, machine in operation (kg), WD-151E 490
Weight, machine in operation (kg), WD-211E 625
Weight, machine in operation (kg), WD-241E 655
Weight, machine in operation (kg), WD-331E 900
Weight, machine in operation (kg), WD-421E 1020
Enclosure protection class (IP) 55