Care and Maintenance
Clean the pre-filter and Multi-protection filter
1. When light up, it is necessary to clean the pre-filter and Multi-p rotection filter.
2. Take off the back cover of main unit , pre-filter is integrated into the back cover.
3. Take off the Multi-protection filter and remove the dust on filter by vacuum them gently.
4. Return the Multi-protection filter to the main unit with the tag side face outward.
5. Return the back cover to the main unit.
6. At this moment, the still light
up, press the ALERT
key for more than 8 seconds until
disappear.
Never wash with water. Vacuum the
Multi-protection filter very gently and
the filter (especially the side with Active
Carbon) may be damaged if too much force
was applied.
WARNING
For Multi-protection filter, it is suggested to replace a new
one every 5 years but it depends on the environment.The life
of Multi-protection filter will be shorten if the room always
occupied with cigarette smoke or dusty air,etc..
N ano-Silver Ion coating and Pre-filter are washable.Make
sure to dry them completely before replacing it to the
machine.
Nano-Silver Ion coating is a filter with nano silver
coating, which is in silver color. It may change color
(such as black or gray) if wash frequently.
Remark:
CAUTION
Defrost
1.
The Defrost
indicator will light up and dehumidifier will start defrost cycle.
During the defrosting operation, the dehumidifiying function
Caution
may intermit.
Please don't turn off the power or pull out the power plug of the dehumidifier during the defrosting
operation.
2.
23
Defrosting is not available
Multi-purpose filter:
Defrosting operation:
46