©Service Competence Center
Kitchen Aid Modular Steam
Function
Kitchen Aid Modular Steam
Boiler Load activation
For Artisan the first load ON has to be always the GRILL during the traditional functions
and Artisan tray during the Steam and Artisan functions, if present into function, the loads
will be switched according to a specific algorithm.
Note: Management of the boiler load respect to the other loads: once all the heating loads
have been distributed during the activation period, the boiler has to be inserted so that its
t-ON time finishes at the end of the period. If the sum of loads power is greater than the
maxim allowed power, the control tries to switch off only one of the heating loads. If this is
not possible all the heating loads will be turned off.
Bto distribute the heating elements, using the required distribution algorithm, the control
decreases the maximum allowed power by the boiler power and then add it when the boiler
has to be inserted.