©Service Competence Center
Components
Cavity Fan
Induction Oven
Mode of operation in the appliance:
The cavity fan is distributing the hot air consistent in the cavity .
The fan speed is fixed because the power is controlled by a relay which is mounted on the
control board. The activation of the fan takes place from the beginning onward in the
most ventilated programs. Sometimes the cavity fan is also activated during some
conventional programs like upper and lower heat with preheat function.
programs the cavity is in a pulsed mode. (This is valid for the Bio Energy Step 2 oven
only)