SYSTEM OPERATION
Initial Start-Up
When power is applied to the unit, the control will briey
display all symbols, and the Snow Flake symbol will be
displayed (if unit is calling for cooling). There may be a
brief delay prior to the evaporator fan turning on. When
the evaporator fan is activated the Fan symbol will be
displayed. The temperature control feature for the
evaporator fan is a feature applicable to WhisperKOOL.
This is the Advance Product Safety Technology (APST),
which ensures that in the possible event of a cooling
deciency, the heat from the indoor fan will not raise the
temperature of the wine cellar, which could otherwise
have an adverse eect on the wine aging process.
Normal System Cycle
After the Bottle probe has reached the set point (all units
are shipped with the set point of 55°F and a dierential
of 1°F). The FON function is an adjustable feature which
allows the customer the convenience of managing
humidity levels in their wine cellar. The FON Function
is a feature that controls the evaporator fan operation
once the set point has been reached. This function allows
the evaporator fan to run and reintroduce humidity
removed during the cooling process. All units come with
this feature turned o. If low humidity is a problem an
increase in this setting will raise the humitiy level. The
FON function is one of the many Customer Preference
Selection features which allow the customer the ability to
ne tune the controls.
Anti Short Cycle
The Anti Short Cycle ensures that the unit will remain o
for a period of 5 minutes after the unit has reached the
set point to allow the pressure in the refrigeration system
to equalize prior to starting the compressor.
Anti Frost Cycle
The Anti Frost Cycle is a precautionary measure, as icing
or frosting of the coil does not occur during normal
operation. The system will go through a defrost cycle
every 4 hours. During the defrost cycle, the indoor fan
will provide air ow across the indoor coil, which will
evaporate any frost accumulation.
Low Ambient Conditions
If the condensing unit is installed outside (which will
allow the condenser to be exposed to low ambient
temperatures), the condenser fan may cycle on and
o. The purpose of the fan cycling is to maintain
the system high side pressure, which will ensure an
adequate refrigeration process. The fan cycling process
is accomplished by way of a Johnson Control attached to
the condensing unit.
Bottle Probe Failure Protection
In the event that a Bottle probe should fail, the APST
(Advance Product Safety Technology) will automatically
transition the Refrigeration Compressor cycles to a pre-
determined time series (based on detailed laboratory
testing), which will ensure that the product is kept within
the safe range.
Remote Key Pad (standard on ducted units)
The remote keypad is designed to give the user the
ability to monitor and change cellar conditions when the
evaporating unit is placed in a remote location outside of
the cellar.

Other manuals for WhisperKool Platinum Split

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WhisperKool Platinum Split and is the answer not in the manual?

WhisperKool Platinum Split Specifications

General IconGeneral
BrandWhisperKool
ModelPlatinum Split
CategoryWine Cooler
LanguageEnglish

Related product manuals